GM-GX/RX Aerogel Rigid/Flexible Coating
Thermal insulation, mold and moisture resistance, waterproofing and leak prevention, water-based and eco-friendly, condensation control, strong adhesion.
Product Features
Thermal insulation, mold and moisture resistance, waterproofing and leak prevention, water-based and eco-friendly, condensation control, strong adhesion. Aerogel coating is a high-performance architectural coating with a range of exceptional properties. It comes in two variants: rigid and flexible. The rigid coating is suitable for building interiors and exteriors, roofs, and industrial facilities, while the flexible coating is designed for fabrics, tents, wall coverings, curtains, and more.
This coating delivers outstanding thermal insulation, effectively reducing heat transfer and minimizing indoor-outdoor temperature differences. In summer, it helps maintain a cool interior, while in winter, it enhances heat retention, lowering energy consumption. The aerogel coating also offers mold and moisture resistance, preventing mildew growth on walls in damp environments and keeping surfaces clean and aesthetically pleasing. Additionally, it provides excellent waterproofing and leak prevention, effectively blocking water penetration and avoiding structural damage caused by seepage.
The aerogel coating features a water-based, eco-friendly formula that is non-toxic and harmless, meeting modern environmental standards. During application, it emits no harmful gases, ensuring safety for both humans and the environment. Moreover, the coating prevents condensation on wall surfaces due to temperature differences, avoiding dampness and mold formation. With superior adhesion, it bonds firmly to various substrates, ensuring long-term stability and durability.
Application Scenarios:
The rigid coating is used for building interiors and exteriors, roofs, and industrial facilities, while the flexible coating is applied to fabrics, tents, wall coverings, curtains, and more.
Performance Parameters
Item | Parameter |
Film Color | Standard white (custom colors available) |
Aerogel Coating | Hydrophobic type |
Density | 450 g/L |
Sanding Property | Can be sanded manually |
▊ Performance Testing
Test Item | Unit | Test Requirement | Test Result | Judgment |
Thermal Conductivity | W/(m·K) | ≤0.065 | 0.029 | Pass |
Thermal Resistance | (m²·K)/W | ≥0.3 | 0.45 | Pass |
Condition in Container | / | No hard lumps after stirring, uniform state | No hard lumps after stirring, uniform state | Pass |
Alkali Resistance (48h) | / | No abnormalities | No abnormalities | Pass |
Water Resistance (48h) | / | No abnormalities | No abnormalities | Pass |
Low-Temperature Storage Stability | / | No deterioration after three cycles | No deterioration after three cycles | Pass |
Water Absorption | g/10min | ≤2.0 | 1.9 | Pass |
Film Flexibility (50mm diameter) | / | No cracks | No cracks | Pass |
Bond Strength (under standard conditions) | MPa | ≥0.6 | 0.7 | Pass |
Initial Drying Crack Resistance (6h) | / | For products with single-layer application thickness ≤1.5mm, 1mm without cracks | 1mm without cracks | Pass |
VOC Content | g/L | ≤100 | 0.5 | Pass |
Formaldehyde Content | mg/kg | ≤50 | Not detected | Pass |
Total Content of Aromatic Hydrocarbons [benzene, toluene, xylene (including ethylbenzene)] | mg/kg | ≤100 | Not detected | Pass |
Total Content of Alkylphenol Ethoxylates | mg/kg | ≤1000 | Not detected | Pass |
Heavy Metal Content (%) | GB/T 26125-2011 (Detection limit: 0.001%) | Lead (Pb) | Not detected | Pass |
Cadmium (Cd) | Not detected | Pass | ||
Mercury (Hg) | Not detected | Pass | ||
Hexavalent Chromium (Cr VI) | Not detected | Pass |
Construction Instructions
Carbon steel, stainless steel, cast iron, aluminum alloy, titanium alloy, high-temperature alloy steel, glass-ceramic plates, ceramics, cement, and other materials (the coating formula varies depending on the substrate. It can be adjusted within a certain range to match different substrates and usage conditions).
Performance Parameters
▊ Application Instructions
Item | Description |
Coverage | 0.48 m²/L (2mm thickness) |
Dilution | Up to 5% water addition based on coating condition |
Recommended Coating Thickness | Above 2mm, apply at least 2 coats |
Curing Time | 8-24 hours |
Application Methods | Rolling, brushing, spraying, troweling |
Operating Temperature | -45°C to 200°C |
▊ Precautions
(1) This product is intended to be applied only by professional construction personnel in industrial fields in accordance with the product manual, material safety data sheet, and recommendations provided on the packaging container.
(2) The construction site should be kept away from sparks, open flames, and other ignition sources. Smoking is strictly prohibited.
(3) When performing spraying operations, protective masks, gloves, and other protective equipment must be worn to avoid skin contact or inhalation of dust.
(4) Before use, the coating must be thoroughly stirred to avoid sedimentation or layering. If the coating is too thick after stirring, an appropriate amount of clean water can be added for dilution, but the amount of water added should not exceed 5% of the total coating volume.
(5) Application can be carried out using rollers, brushes, or spraying equipment. During application, ensure even coverage without missed spots. It is recommended to apply in two coats, allowing the first coat to dry before applying the second, to ensure coating thickness and uniformity.
(6) The construction site should be well-ventilated to avoid prolonged exposure to high concentrations of coating materials.